{"title":"Gas Scavenging","description":"","products":[{"product_id":"iso-miser-anaesthetic-circle-absorber","title":"ISO-MISER Anaesthetic Circle Absorber","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eIso‑Miser small animal circle absorber\u003c\/strong\u003e is designed for patients \u003cstrong\u003e10 kg and above\u003c\/strong\u003e, providing efficient CO₂ absorption and smooth, low‑resistance breathing performance. Supplied complete with patient breathing tubing, a \u003cstrong\u003e2‑litre reservoir bag\u003c\/strong\u003e, and a \u003cstrong\u003e30 mm to 22 mm scavenging connector\u003c\/strong\u003e, it offers a ready‑to‑use solution for modern veterinary anaesthesia setups.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDeveloped as a rationally engineered replacement for the traditional polycarbonate “hamster wheel” absorber, the Iso‑Miser eliminates the need for stand‑off fittings and improves overall usability. Its \u003cstrong\u003e22 mm female fresh‑gas inlet\u003c\/strong\u003e, positioned directly behind the inspiratory port, allows direct mounting onto most contemporary \u003cstrong\u003e\u003cspan role=\"button\" data-url=\"copilot-action:\/\/composer-send?text=What%20does%20an%20anaesthetic%20machine%20do\" tabindex=\"0\"\u003eanaesthetic machines\u003c\/span\u003e\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSmall animal circle absorber\u003c\/strong\u003e for patients \u003cstrong\u003e10 kg+\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFresh‑gas inlet: \u003cstrong\u003e22 mm female taper\u003c\/strong\u003e, positioned for direct machine mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLarge directional valves\u003c\/strong\u003e for minimal resistance and smooth gas flow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMushroom valve\u003c\/strong\u003e in scavenging port relieves at \u003cstrong\u003e2 cm H₂O\u003c\/strong\u003e, maintaining ideal back‑pressure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes \u003cstrong\u003eDraeger CoAxial breathing circuit\u003c\/strong\u003e – a unique tube‑within‑tube design offering:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVery low resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eImproved humidity and heat conservation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStreamlined, clutter‑free patient‑end setup\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1.5 m length, ideal for circle absorbers, including Iso‑Miser\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003cstrong\u003e\u003cspan role=\"button\" data-url=\"copilot-action:\/\/composer-send?text=Tell%20me%20about%20veterinary%20anaesthesia%20equipment\" tabindex=\"0\"\u003eveterinary anaesthesia\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eWhat’s Included\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDraeger CoAxial patient breathing tubing \u003c\/strong\u003eor\u003c\/span\u003e\u003cspan\u003e 2000000 22 mm Flextube breathing system (≥1.6 m) upon request at time of ordering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e2‑litre reservoir bag\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e30 mm to 22 mm scavenging connector\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eNote: Main image shows 2000000 tubing.\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Photon Surgical Systems Ltd","offers":[{"title":"Default Title","offer_id":55971576414586,"sku":"N-ANA-10-50-028","price":210.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/6641\/0106\/files\/N-ANA-10-50-028_1_ebf9045a-d03f-4e0c-8798-46d7e98c2812.jpg?v=1759258690"},{"product_id":"disposable-anaesthetic-gas-absorbers","title":"Disposable Anaesthetic Gas Absorbers","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e\u003cspan role=\"button\" data-url=\"copilot-action:\/\/composer-send?text=What%20is%20a%20waste%20gas%20canister\" tabindex=\"0\"\u003ewaste gas canister\u003c\/span\u003e\u003c\/strong\u003e is designed to safely \u003cstrong\u003eabsorb organic anaesthetic gases\u003c\/strong\u003e, such as halothane and isoflurane - from the expiratory limb of a veterinary anaesthetic circuit. Filled with \u003cstrong\u003eactivated carbon\u003c\/strong\u003e, it prevents harmful waste gases from entering the working environment. Because \u003cstrong\u003enitrous oxide is not absorbed\u003c\/strong\u003e, this method is unsuitable for systems using N₂O. The canister must be \u003cstrong\u003eweighed regularly\u003c\/strong\u003e to ensure it is replaced before saturation, as a saturated canister will no longer absorb gases.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow the Canister Functions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eConnected directly to the \u003cstrong\u003e\u003cspan role=\"button\" data-url=\"copilot-action:\/\/composer-send?text=What%20is%20anaesthetic%20scavenging%20tubing\" tabindex=\"0\"\u003escavenging tubing\u003c\/span\u003e\u003c\/strong\u003e from the patient circuit’s expiratory (scavenge) valve, the canister traps organic vapours as they pass through the charcoal bed. Once the charcoal reaches its absorption limit, waste gases will bypass the medium and be released into the room, making monitoring essential for staff safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan role=\"button\" data-url=\"copilot-action:\/\/composer-send?text=What%20is%20a%2022mm%20anaesthetic%20connector\" tabindex=\"0\"\u003e22 mm male inlet\u003c\/span\u003e\u003c\/strong\u003e — standard connection for direct attachment to scavenging tubing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eActivated carbon filling\u003c\/strong\u003e — absorbs up to \u003cstrong\u003e800 g\u003c\/strong\u003e of organic anaesthetic agents.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNot suitable for N₂O\u003c\/strong\u003e — nitrous oxide is not absorbed by charcoal.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApprox. 28 hours of constant-use capacity\u003c\/strong\u003e — varies with gas flow and concentration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eControlled incineration disposal\u003c\/strong\u003e — required once saturated.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSold individually, as a pack of 6 or 10.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Photon Surgical Systems Ltd","offers":[{"title":"Individual","offer_id":56827340685690,"sku":"N-ANA-10-90-010 x1","price":15.83,"currency_code":"GBP","in_stock":true},{"title":"6 Pack","offer_id":56827340718458,"sku":"N-ANA-10-90-010 x6","price":95.0,"currency_code":"GBP","in_stock":true},{"title":"10 pack","offer_id":56827340751226,"sku":"N-ANA-10-90-010 x10","price":112.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/6641\/0106\/files\/FREEGA.png?v=1778779502"},{"product_id":"activent-low-cost-active-pollution-scavenging-system-with-built-in-air-break","title":"ACTIVENT Active Pollution Scavenging System (with built-in Air-Break)","description":"\u003cp\u003eOur Activents are a fan‑driven anaesthetic waste‑gas exhaust system designed to safely remove all anaesthetic waste gases - including nitrous oxide - from the operating environment. Unlike Fluosorbers, which can present bacterial hazards, Activent provides active, reliable extraction while incorporating built‑in safety features to prevent both positive and negative pressure at the patient end. Typically wall‑mounted beside the anaesthetic workstation, it ensures a clean, compliant and efficient scavenging solution.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves \u003cstrong\u003eall anaesthetic waste gases\u003c\/strong\u003e, including nitrous oxide\u003c\/li\u003e\n\u003cli\u003eSafer alternative to Fluosorbers, which carry bacterial contamination risks\u003c\/li\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003ewall mounting\u003c\/strong\u003e beside the anaesthetic workstation\u003c\/li\u003e\n\u003cli\u003eBuilt‑in \u003cstrong\u003efixed 3‑litre reservoir\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour top‑mounted inlet vents\u003c\/strong\u003e provide an open‑to‑atmosphere \u003cem\u003eAIR‑BREAK\u003c\/em\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents positive or negative pressure at the patient's end\u003c\/li\u003e\n\u003cli\u003ePrevents gas spillover into the work environment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDraws approx. \u003cstrong\u003e8 L\/min of room air\u003c\/strong\u003e, mixing it with waste gases delivered via:\n\u003cul\u003e\n\u003cli\u003eStandard \u003cstrong\u003e30 mm connectors\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e22 mm flexible scavenging tubing\u003c\/strong\u003e (included)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eActively propels waste gases to the disposal point \u003cstrong\u003eup to 15 metres away\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWe advise that these are installed with an external outlet above head height for health and safety\u003c\/li\u003e\n\u003cli\u003eIlluminated \u003cstrong\u003eON\/OFF rocker switch\u003c\/strong\u003e with red power indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGreen light\u003c\/strong\u003e indicates fan operation (near‑silent running)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cstrong\u003eActivent Solo\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eSingle‑station, fan‑driven waste‑gas exhaust system\u003c\/li\u003e\n\u003cli\u003eRemoves all anaesthetic waste gases and vapours from the operating suite\u003c\/li\u003e\n\u003cli\u003eTypically mounted adjacent to the anaesthetic workstation\u003c\/li\u003e\n\u003cli\u003eRecommended external termination via \u003cstrong\u003e22 mm FloPlast\u003c\/strong\u003e \u003cstrong\u003etee‑piece \u003c\/strong\u003eto prevent wind from travelling up the tubing (not included)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cstrong\u003eActivent Multi\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes a \u003cstrong\u003eone‑way valve\u003c\/strong\u003e allowing multiple Activent units to be connected to a single external exhaust pipe\u003c\/li\u003e\n\u003cli\u003eSimplifies installation in multi‑room or multi‑machine practices\u003c\/li\u003e\n\u003cli\u003eStill requires \u003cstrong\u003eone Activent per anaesthetic machine\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTop end includes \u003cstrong\u003eAIR‑BREAK\u003c\/strong\u003e with four inlet holes\u003c\/li\u003e\n\u003cli\u003eDraws approx. \u003cstrong\u003e8 L\/min\u003c\/strong\u003e of air to mix and propel waste gases\u003c\/li\u003e\n\u003cli\u003ePush‑button \u003cstrong\u003eON\/OFF\u003c\/strong\u003e with power indicator and green fan‑running LED\u003c\/li\u003e\n\u003cli\u003eRecommended external termination via \u003cstrong\u003e22 mm FloPlast\u003c\/strong\u003e \u003cstrong\u003etee‑piece \u003c\/strong\u003eto prevent wind from travelling up the tubing (not included)\u003c\/li\u003e\n\u003cli\u003eEffective performance depends on local factors:\n\u003cul\u003e\n\u003cli\u003eLength of tubing\u003c\/li\u003e\n\u003cli\u003eInternal diameter\u003c\/li\u003e\n\u003cli\u003eSmooth‑bore vs. convoluted pipework\u003c\/li\u003e\n\u003cli\u003eNumber of 90° bends\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eRegulatory Note\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRCVS Practice Standards (section 5.12, paragraph 4):\u003c\/strong\u003e\u003cbr\u003e\u003cem\u003e“If a sophisticated active scavenging system is in operation, it must be serviced annually. A test certificate must be available and is an acceptable alternative to personal dosimetry.”\u003c\/em\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eCost Efficiency\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eActivents can pay for themselves in as little as 12 months.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExample comparison:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAnnual use of 12 Fluosorbers at £24 each = \u003cstrong\u003e£288 per year\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eActivent eliminates ongoing absorbent purchases\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003e\u003cstrong\u003eWhat’s Included\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e22 mm–22 mm straight connector\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e22 mm–30 mm connector\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eScavenging tubing for \u003cstrong\u003eAPL valve → Activent\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWall‑mounting \u003cstrong\u003e‘V’ plate and bracket\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAC to adjustable DC Power Supply Unit\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Starter Kit\u003c\/strong\u003e, providing:\n\u003cul\u003e\n\u003cli\u003eTubing and connectors to route exhaust upward\u003c\/li\u003e\n\u003cli\u003eRight‑angled connector\u003c\/li\u003e\n\u003cli\u003eWall penetration (22 mm hole)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eThe system may be extended up to 15 metres\u003c\/strong\u003e using standard domestic \u003cstrong\u003e21.5 mm overflow tubing\u003c\/strong\u003e, available from common DIY retailers.\u003c\/p\u003e","brand":"Photon Surgical Systems Ltd","offers":[{"title":"Solo","offer_id":56640710738298,"sku":"N-ANA-10-90-007","price":475.0,"currency_code":"GBP","in_stock":true},{"title":"Multi","offer_id":56640710771066,"sku":"N-ANA-10-90-008","price":575.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/6641\/0106\/files\/N-ANA-10-90-007.jpg?v=1772461671"},{"product_id":"kab-anaesthetic-circle-absorber","title":"KAB Anaesthetic Circle Absorber","description":"\u003cdiv\u003e\n\u003cp\u003eThe KAB CO₂ Absorber is designed for effective carbon dioxide removal in closed or semi‑closed breathing circuits using soda lime. The unit features an integrated, adjustable APL valve with a built‑in scavenging port, offering a compact and efficient solution for small animal anaesthesia.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRemoves CO₂ from closed or semi‑closed breathing systems via \u003cstrong\u003esoda lime\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntegrated \u003cstrong\u003eadjustable APL valve\u003c\/strong\u003e with scavenging port\u003c\/li\u003e\n\u003cli\u003eIf purchasing for the first time, the \u003cstrong\u003emetal KABTP mounting plate\u003c\/strong\u003e is required\u003c\/li\u003e\n\u003cli\u003eA \u003cstrong\u003elong extension\u003c\/strong\u003e may be needed when the common gas outlet sits close to the vaporiser and additional clearance is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF‑Circle Mark 1\u003c\/strong\u003e small‑animal circle absorber for patients \u003cstrong\u003e10 kg and above\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow flow resistance throughout the system\u003c\/li\u003e\n\u003cli\u003eLow‑resistance \u003cstrong\u003eone‑way valves\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaffled canister\u003c\/strong\u003e design ensures gas passes effectively over the soda lime\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial circle breathing tubes\u003c\/strong\u003e reduce drag on the patient\u003c\/li\u003e\n\u003cli\u003eCan be fitted directly to the oxygen outlet when the canister can be positioned close to the anaesthetic machine\u003c\/li\u003e\n\u003cli\u003eIf required, use a \u003cstrong\u003e22 mm T‑piece\u003c\/strong\u003e to attach it to the anaesthetic machine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutoclavable\u003c\/strong\u003e for high‑level sterilisation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAdditional Note\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA \u003cstrong\u003e22M–22M elbow connector with 7.6 mm port\u003c\/strong\u003e is ideal if the \u003cstrong\u003ebag mount\u003c\/strong\u003e on your KAB absorber has been lost or damaged.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Photon Surgical Systems Ltd","offers":[{"title":"Default Title","offer_id":56640390365562,"sku":"N-ANA-10-50-007","price":295.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/6641\/0106\/files\/N-ANA-10-50-007_111d6603-173b-41aa-adea-a56cd1a73ec5.jpg?v=1772481995"},{"product_id":"spherasorb™-medical-grade-soda-lime-5l","title":"Spherasorb™  Medical Grade Soda Lime 5L","description":"\u003cdiv\u003e\n\u003cp\u003eSpherasorb™ is a high‑performance CO₂ absorbent formulated to deliver maximum safety, reliability and absorption efficiency in medical and veterinary anaesthesia systems. Its chemistry is engineered to avoid common absorbent‑related risks while maintaining excellent CO₂ capacity.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eQuality\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLong history of safe and effective use in anaesthesia\u003c\/li\u003e\n\u003cli\u003eMeets all requirements of both the \u003cstrong\u003eUnited States Pharmacopoeia (USP)\u003c\/strong\u003e and \u003cstrong\u003eBritish Pharmacopoeia (BP)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eColour Indicator\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMedical‑grade formulation includes a white‑to‑violet or pink-to-white colour indicator\u003c\/li\u003e\n\u003cli\u003eGranules change colour when CO₂ absorption is exhausted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOnly \u003cstrong\u003e1.5% sodium hydroxide\u003c\/strong\u003e, reducing the risk of complications\u003c\/li\u003e\n\u003cli\u003eContains \u003cstrong\u003ezeolite\u003c\/strong\u003e to minimise drying\u003c\/li\u003e\n\u003cli\u003eManufactured as \u003cstrong\u003e3–4 mm spherical granules\u003c\/strong\u003e to:\n\u003cul\u003e\n\u003cli\u003eReduce dust\u003c\/li\u003e\n\u003cli\u003eProvide even gas flow\u003c\/li\u003e\n\u003cli\u003eMaximise CO₂ absorption efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSold in a \u003cstrong\u003e5L jerican\u003c\/strong\u003e (available in other formats on request)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Photon Surgical Systems Ltd","offers":[{"title":"White to Violet","offer_id":56645388599674,"sku":"N-ANA-10-90-016","price":24.27,"currency_code":"GBP","in_stock":true},{"title":"Pink to White","offer_id":56645388632442,"sku":"N-ANA-10-90-017","price":24.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/6641\/0106\/files\/N-ANA-10-90-016.jpg?v=1772518958"},{"product_id":"soda-lime-funnel","title":"Soda Lime Funnel","description":"\u003cdiv\u003e\n\u003cp\u003eA practical, easy‑to‑use funnel designed specifically for clean, efficient filling of soda lime canisters used in anaesthetic breathing systems. Its wide top opening and stable design help reduce spills and waste, ensuring quick, accurate refills with minimal mess. Ideal for both veterinary and medical anaesthesia environments.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003eeasy filling of soda lime canisters\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHelps reduce \u003cstrong\u003espillage and dust\u003c\/strong\u003e during refilling\u003c\/li\u003e\n\u003cli\u003eWide top opening for efficient pouring\u003c\/li\u003e\n\u003cli\u003eDurable, easy‑clean construction\u003c\/li\u003e\n\u003cli\u003eSuitable for all standard soda lime absorbers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Photon Surgical Systems Ltd","offers":[{"title":"Default Title","offer_id":56645397807482,"sku":"N-ANA-10-90-004","price":6.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/6641\/0106\/files\/N-ANA-10-90-004.jpg?v=1772536463"}],"url":"https:\/\/photonsurgicalsystems.co.uk\/collections\/gas-scavenging.oembed","provider":"Photon Surgical Systems Ltd","version":"1.0","type":"link"}