{"product_id":"shalya-vista-ve-electrosurgery-unit-monopolar-bipolar-vessel-sealing","title":"Shalya Vista VE Electrosurgery Unit – Monopolar, Bipolar \u0026 Vessel Sealing","description":"\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003e\u003cspan data-url=\"copilot-action:\/\/composer-send?text=What%20is%20the%20Shalya%20Vista%20VE\" role=\"button\" tabindex=\"0\"\u003eShalya Vista VE\u003c\/span\u003e\u003c\/strong\u003e is a powerful 400W electrosurgical platform combining \u003cstrong\u003evessel sealing\u003c\/strong\u003e, \u003cstrong\u003emonopolar\u003c\/strong\u003e, \u003cstrong\u003ebipolar\u003c\/strong\u003e, and \u003cstrong\u003eRFaST radiofrequency ablation scalpel technology\u003c\/strong\u003e. Designed for versatility and precision, it supports advanced surgical workflows with reusable vessel‑sealing attachments capable of sealing vessels up to \u003cstrong\u003e7 mm\u003c\/strong\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eVessel sealing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBipolar\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMonopolar\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eWhat Is Vessel Sealing?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan data-url=\"copilot-action:\/\/composer-send?text=Explain%20vessel%20sealing%20technology\" role=\"button\" tabindex=\"0\"\u003eVessel sealing\u003c\/span\u003e\u003c\/strong\u003e uses a combination of energy and calibrated pressure from the handpiece. When activated, the vessel walls are compressed, and the \u003cstrong\u003ecollagen and elastin\u003c\/strong\u003e fuse to create a strong, permanent seal.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eBenefits of Vessel Sealing\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReliable, consistent wall fusion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMinimal thermal spread\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReduced charring and sticking\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e10 mm handpiece seals vessels up to \u003cstrong\u003e7 mm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBloodless field\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eNo sutures or foreign material\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTime‑saving workflow\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eWhy Vessel Sealing Requires Advanced Technology\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eVessel sealing demands \u003cstrong\u003ehigh current\u003c\/strong\u003e, \u003cstrong\u003ehigh pressure\u003c\/strong\u003e, and \u003cstrong\u003elow impedance\u003c\/strong\u003e performance—far beyond standard bipolar energy. The Vista VE is engineered to deliver this safely and consistently, with reusable, autoclavable handpieces at an accessible price point.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch1\u003e\u003cstrong\u003eBipolar vs Vessel Sealing \u003c\/strong\u003e\u003c\/h1\u003e\n\u003cdiv\u003e\n\u003cdiv aria-label=\"Scrollable table\" role=\"region\" tabindex=\"0\"\u003e\n\u003ctable style=\"width: 38.715278%; height: 232px;\" height=\"183\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 37.333332px;\"\u003e\n\u003cth style=\"width: 36.280883%; height: 37.333332px;\"\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 23.016904%; height: 37.333332px;\"\u003e\u003cstrong\u003e\u003cspan data-url=\"copilot-action:\/\/composer-send?text=What%20is%20bipolar%20electrosurgery\" role=\"button\" tabindex=\"0\"\u003eBipolar\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 37.451234%; height: 37.333332px;\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eV.Sealing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 18.666666px;\"\u003e\n\u003ctd style=\"width: 36.280883%; height: 18.666666px;\"\u003e\u003cspan\u003ePressure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.016904%; height: 18.666666px;\"\u003e\u003cspan\u003eLow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 37.451234%; height: 18.666666px;\"\u003e\u003cspan\u003eHigh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.666666px;\"\u003e\n\u003ctd style=\"width: 36.280883%; height: 18.666666px;\"\u003e\u003cspan\u003eCurrent\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.016904%; height: 18.666666px;\"\u003e\u003cspan\u003eLow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 37.451234%; height: 18.666666px;\"\u003e\u003cspan\u003eHigh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.666666px;\"\u003e\n\u003ctd style=\"width: 36.280883%; height: 18.666666px;\"\u003e\u003cspan\u003eResistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.016904%; height: 18.666666px;\"\u003e\u003cspan\u003eHigh\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 37.451234%; height: 18.666666px;\"\u003e\u003cspan\u003eLow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 37.333332px;\"\u003e\n\u003ctd style=\"width: 36.280883%; height: 37.333332px;\"\u003e\n\u003cspan\u003eArea \u003c\/span\u003e\u003cspan\u003eof \u003c\/span\u003e\u003cspan\u003eContact\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 23.016904%; height: 37.333332px;\"\u003e\u003cspan\u003eLow\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 37.451234%; height: 37.333332px;\"\u003e\u003cspan\u003eHigh\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.666666px;\"\u003e\n\u003ctd style=\"width: 36.280883%; height: 18.666666px;\"\u003e\u003cspan\u003eVoltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 23.016904%; height: 18.666666px;\"\u003e\u003cspan\u003eHigh\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 37.451234%; height: 18.666666px;\"\u003e\u003cspan\u003eLow\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eAdvantages of Shalya Vessel Sealing\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlarms if tissue is not held correctly (too thick, too thin, or incomplete grasp)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety cut‑out if blood, saline or clips are detected\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSafety cut‑out if impedance fails to reduce, limiting thermal spread\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMinimal sticking and charring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSeals withstand \u003cstrong\u003e3× normal systolic pressure\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIndependent activation for Sealer, Bipolar CUT \u0026amp; Bipolar COAG\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct Features (Bullet‑Point Format)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTouch Screen LCD Interface\u003c\/strong\u003e – 5.7″ resistive touchscreen with on‑screen mode descriptions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCOMBO Generator Technology\u003c\/strong\u003e – Vessel sealing, saline plasma bipolar resection, and high‑performance ESU in one unit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSmart Unit\u003c\/strong\u003e – Automatic monitoring and instant response for consistent cutting and coagulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e6SENSE Technology\u003c\/strong\u003e – Advanced \u003cstrong\u003e\u003cspan data-url=\"copilot-action:\/\/composer-send?text=Explain%20tissue%20feedback%20technology\" role=\"button\" tabindex=\"0\"\u003etissue feedback system\u003c\/span\u003e\u003c\/strong\u003e monitoring voltage, current, power, tissue density and electrode contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFully Microprocessor‑Controlled\u003c\/strong\u003e – High clinical precision\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUser Programmable\u003c\/strong\u003e – 100 user‑settable programs with case names\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRecall Function\u003c\/strong\u003e – Automatically restores last used settings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDual Mono Mode (Optional)\u003c\/strong\u003e – Independent power\/mode settings for two monopolar channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e2SiCoag (Optional)\u003c\/strong\u003e – Two simultaneous coagulation outputs with independent control\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBipolar Cut \u0026amp; Coag\u003c\/strong\u003e – Independent settings and activation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBiCoag Alarm\u003c\/strong\u003e – Audio feedback after bipolar coag completion\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDual Vessel Sealing\u003c\/strong\u003e – Seals up to 7 mm with reusable open \u0026amp; laparoscopic attachments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAuto Stop\u003c\/strong\u003e – Audio indication when sealing cycle completes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTissue ReHold Alarm\u003c\/strong\u003e – Alerts if tissue is not grasped correctly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSaline Resection\u003c\/strong\u003e – Bipolar saline plasma cut (two modes) and coag (two modes)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSaline Safety Alarm\u003c\/strong\u003e – Alerts for electrode disconnection or non‑saline activation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e2 Endo Modes\u003c\/strong\u003e – Pulse‑interval controlled pulse cut for polypectomy \u0026amp; papillotomy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eArgon Beam Coagulator Upgradable\u003c\/strong\u003e – Expandable platform\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePREM\u003c\/strong\u003e – Patient return electrode monitoring for safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSelf Diagnosis\u003c\/strong\u003e – Continuous system checks with error code display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eWhat’s Included\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eShalya Vista VE Electrosurgical Unit with Vessel Sealing System\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUser manual CD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMains cable\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eE201\u003c\/strong\u003e: Single paddle footswitch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eE202\u003c\/strong\u003e: Double paddle footswitch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eE203\u003c\/strong\u003e: Small double paddle footswitch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eExtras\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"VCuter\" href=\"https:\/\/photonsurgicalsystems.co.uk\/products\/shalya-vector-vcuter-10mm-electrosurgical-handpiece?_pos=1\u0026amp;_sid=f7ad725c0\u0026amp;_ss=r\u0026amp;variant=56052058718586\"\u003e10 mm Vcutter sealing\/cutting handpiece\u003c\/a\u003e\u003c\/strong\u003e (18 cm or 36 cm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"Axer 5\" href=\"https:\/\/photonsurgicalsystems.co.uk\/products\/shalya-axer-5-advanced-5mm-handpiece?_pos=2\u0026amp;_psq=axer\u0026amp;_ss=e\u0026amp;_v=1.0\u0026amp;variant=56050347835770\"\u003eAxer 5\u003c\/a\u003e \u003c\/strong\u003e– Advanced 5 mm Laparoscopic Instrument\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"Axer 10\" href=\"https:\/\/photonsurgicalsystems.co.uk\/products\/shalya-axer-5-advanced-10mm-handpiece?_pos=1\u0026amp;_psq=axer\u0026amp;_ss=e\u0026amp;_v=1.0\u0026amp;variant=56827151221114\"\u003eAxer 10\u003c\/a\u003e \u003c\/strong\u003e- Advanced 10 mm Laparoscopic Instrument\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca title=\"5mm V\" href=\"https:\/\/photonsurgicalsystems.co.uk\/products\/shalya-vseal-bipolar-5mm-handpiece?_pos=1\u0026amp;_psq=5mm\u0026amp;_ss=e\u0026amp;_v=1.0\u0026amp;variant=56050380734842\"\u003e5 mm VSeal bipolar cut\/coag handpiece \u003c\/a\u003e\u003c\/strong\u003e(18 cm or 36 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e1‑year warranty\u003c\/strong\u003e on main Shalya base units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eQ\u0026amp;A\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan the Vista VE be used with solid plates?\u003c\/strong\u003e Yes — solid plates can be used in both single and dual areas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCan we use pre‑gelled disposable solid plates?\u003c\/strong\u003e Yes — ensure the area is neatly shaved before application.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWhat settings are commonly used?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eESU:\u003c\/strong\u003e 15W bipolar, 25W cut‑coag, 40W cut\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSealing:\u003c\/strong\u003e Level 2 optimised programme (Cut 50W, Coag 25W)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Photon Surgical Systems Ltd","offers":[{"title":"Default Title","offer_id":56043994513786,"sku":"N-ESU-20-10-008","price":6396.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0907\/6641\/0106\/files\/N-ESU-20-10-008_a0c4a48f-1139-4498-b2d5-6ece888ce625.jpg?v=1771873839","url":"https:\/\/photonsurgicalsystems.co.uk\/products\/shalya-vista-ve-electrosurgery-unit-monopolar-bipolar-vessel-sealing","provider":"Photon Surgical Systems Ltd","version":"1.0","type":"link"}