Viruzyme VE Enzyme based Biological Endoscope Cleaner

Excl VAT 20% - calculated at checkout

Viruzyme® Ve is a high‑performance biological cleaner formulated with a powerful blend of five enzymes to ensure thorough decontamination of medical, surgical, dental, and endoscopic instruments. Designed to break down and remove even the most stubborn organic contaminants, it delivers exceptional cleaning results while protecting delicate instrument surfaces.

This Class I medical device is particularly effective at dissolving high levels of proteins, fats, and organic residues—including dried blood and tissue—making it an essential part of any modern infection‑control protocol. Safe for use on all surfaces, Viruzyme® Ve provides reliable cleaning performance at both ambient and elevated temperatures.

Compatible with manual cleaning, ultrasonic baths, washer/disinfectors, and Automated Endoscope Reprocessors (AER), it supports consistent, efficient cleaning across all stages of instrument reprocessing.

Key Features

  • Highly effective biological cleaner for proteinaceous and organic contaminants

  • Five‑enzyme formula: protease, amylase, lipase, cellulase, and mannanase

  • Suitable for sensitive instrument materials

  • Pleasant odour for improved user comfort

  • Excellent material compatibility

  • Non‑fixative and non‑corrosive—protects delicate coatings

  • Rapid cleaning action: 5‑minute immersion at 20–55°C

  • Cost‑effective solution for routine decontamination

Application

Manual & Ultrasonic Cleaning of Instruments and Equipment

  • Standard dosage: Add 2–10 ml of Viruzyme® Ve per 1 litre of water (0.2–1.0%).

  • For heavy contamination: Use up to 40 ml per litre (4%) when dealing with high levels of organic material or hazardous contaminants.

  • Soaking time: Immerse parts for 5–10 minutes in the diluted solution.

    • For dried‑on protein deposits or low‑temperature solutions, extend soaking up to 20 minutes.

  • After soaking:

    • Brush to remove gross debris (manual cleaning)

    • Rinse thoroughly with clean water

    • Or transfer directly to the next cleaning stage (washer/disinfector, ultrasonic unit, or AER)

Manual Cleaning Parameters

  • Water: Warm tap water

  • Time: 5–20 minutes

  • Temperature: Ambient

  • Dosage: 2–10 ml/L (0.2–1.0%)

Pair this with 'Medistel' for a two-step process to clean and disinfect your endoscopy equipment.

N-END-50-30-010 x 3

We aim to offer the most competitive price, but if you can find the same item elsewhere for a better price then let us know and we will try to match or better the price! At Photon Surgical Systems we pride ourselves on our customer service and are happy to offer as much help as needed regardless of the query size. Contact our team today!

We aim to offer the most competitive price, but if you can find the same item elsewhere for a better price then let us know and we will try to match or better the price! At Photon Surgical Systems we pride ourselves on our customer service and are happy to offer as much help as needed regardless of the query size. Contact our team today!

FAQ

Yes! We understand that choosing equipment from a website can be a challenge, which is why our knowledgeable sales team are available to visit your practice with a range of our demo veterinary equipment, so that you can sample our products and discuss your needs with our team before making any decisions.

Yes! We can ship our equipment all over the world! To place an order for delivery outside of the UK, click here to speak to one of our sales experts directly. Our team will be able to help you every step of the way, from helping you choose which equipment will best suit your individual needs, to finding the most cost effective international shipping options and more.

Our knowledgeable team of engineers are here to help you every step of the way, from installation, to breakdowns and servicing too! Click here to find out more..

You can place an order with us via our website, or you can contact our sales team and place an order with them directly too. Once an order is placed, a member of our team will be in contact to keep you informed of estimated delivery dates and help if you have any further questions too. Please kindly note that our team will do their best to get back to your order enquiry as quickly as possible, for any urgent orders please call us on 01452 347 101.

If you are placing an order via our website we require payment at the checkout, with a range of payment options available.

Alternatively you can contact our sales team and place an order with them directly via telephone or email. We can offer 14 day payment terms for customers who have placed 5+ orders with us, where you will receive an invoice following the despatch of your order. 14 day payment terms are only available when placing orders directly with our sales team. For new customers, we require pro forma payment for the first 5 orders placed with us. For any orders over £5,000 we require pro forma payment.

We work closely with Vector Finance and are happy to discuss other finance options to suit your needs.

If you would like to find out more about our payment terms and options available then please contact our team - We are here to help you every step of the way.